Must-Read for Electroplating Plant Owners! 3-Minute Self-Check Guide to Combat Burner "Corrosion Killers" - Save Thousands in Annual Maintenance Costs_Foshan Shunde Zhibo Burner Manufacturing Co., Ltd.


    1. 香蕉国产精品,香蕉钻洞视频,香蕉成年人视频,香蕉视频APP污污污黄片

      Home > Company News

      Must-Read for Electroplating Plant Owners! 3-Minute Self-Check Guide to Combat Burner "Corrosion Killers" - Save Thousands in Annual Maintenance Costs

      Time:2025-04-24 Click:

      Longevity Secrets for Your Electroplating Burner: 3 High-Risk Component Inspection Methods:

      一、External Inspection (Completed in 3 Minutes)

      1️⃣ Burner Housing Surface  
      ✔️ Check: Peeling coating/rust/discoloration  
      ⚠️ Standard: No rust, intact coating  
      🔧 Tools: Visual inspection + flashlight  

      2️⃣ Pipe Connections
      ✔️ Check: Leaks/rust at flanges/threads  
      ⚠️ Standard: Tight seals, no corrosion  
      🔧 Tools: Wipe with tissue paper  

      3️⃣ Exhaust Outlet
      ✔️ Check: Carbon buildup/acidic condensate on inner walls  
      ⚠️ Standard: No sticky corrosive residue  
      🔧 Tools: Endoscope (optional)




      二、Core Internal Inspection (Requires Shutdown)

      🔥 Combustion Chamber Refractory Layer
      ✔️ Check: Cracks/spalling in refractory material 
      ❗ Risk:Acidic gases accelerate erosion!
       🔧 Method: Tap to listen for hollow sounds (indicates damage) 

      🌀 Heat Exchanger Fins
      ✔️ Check: Acid mist condensate/corrosion holes  
      🔧 Method: Clean with soft brush + compressed air

      ⚡ Electrodes & Igniter Plates
      ✔️ Check: Ceramic insulator cracks/metal oxidation  
      🔧 Tools: Multimeter to test insulation resistance 




      三、Electroplating Workshop-Specific Checks  

      ⚠️ Acid/Alkali Gas Protection 
      ✔️ Action: Test ambient air around equipment with pH test paper  
      🔌 Grounding Resistance Test 
      ✔️ Standard: Grounding resistance ≤4Ω  




      四、Emergency Response

      ⛔Immediately Shut Down the Machine if the Following Issues are Detected: 
      → Perforated heat exchanger fins  
      → Large-area spalling in combustion chamber refractory layer  
      → Electrode/ion rod insulation resistance <10MΩ  


      ⏰ Pro Tip:Perform these checks monthly to extend burner lifespan by 2-3 years and slash maintenance costs! 